Influence of sample matrix and filter fixation on LIBS signal in analysis of algae on filter

Logo poskytovatele

Varování

Publikace nespadá pod Ústav výpočetní techniky, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

HRDLIČKA Aleš HORSKÁ Jana HEGROVA Jitka BUCKOVA Martina PROCHAZKA David BUDAY Jakub PORIZKA Pavel KANICKÝ Viktor KAISER Jozef

Rok publikování 2025
Druh Článek v odborném periodiku
Časopis / Zdroj JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://pubs.rsc.org/en/content/articlelanding/2025/ja/d5ja00236b
Doi https://doi.org/10.1039/d5ja00236b
Klíčová slova INDUCED BREAKDOWN SPECTROSCOPY; LASER
Popis This study first reveals the matrix effect mechanism of filter fixation on laser-induced breakdown spectroscopy (LIBS) quantitative analysis of algae, providing a methodological reference for in situ environmental detection. A collinear 1064 nm double pulse LIBS was used for analysis of green algae on a cellulose filter. Intensities of the contaminant elements Zn, Ni and those of some matrix lines of C I, Ca I, II, K I, Mg I, II, Mn I, II, Na I, H I, O I were measured and compared for various numbers of tape layers used for the filter fixation onto a microscope glass slide. This arrangement simulated surface modifications which can substantially lower the measured intensities. Maximum intensities were measured for 1 or 2 tape layers and lowest intensities for 6 layers for filters with contaminated algae; however, this intuitive result was not yielded for non-contaminated algae. It might indicate substantial changes of the filter properties and interaction with the laser beam at minimal changes of the analyte. This is crucial for quantitative analysis influenced not only by the sample fixation and surface quality but also by the composition of the filtered algae. The results were, to some extent, supported by principal component analysis, a shadowgraphic study of a single pulse microplasma shockwave, crater size and by simplified geometric and thermodynamic models. These were based on a spherical shape and full validity of the Boltzmann distribution respectively. The relatively small changes of the abovementioned parameters are in contrast to important changes of the lines intensities measured from the microplasma on the contaminated samples.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info