Rapid Activation of 3D-Printed Carbon Electrodes by Atmospheric Air Plasma: Toward Electrochemical Drug Analysis

Varování

Publikace nespadá pod Ústav výpočetní techniky, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

KOVAC Miroslav GREGOVA Katarina SVORC Lubomir ZAŽÍMAL František HOMOLA Tomáš GEMEINER Pavol

Rok publikování 2025
Druh Článek v odborném periodiku
Časopis / Zdroj ACS Omega
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://pubs.acs.org/doi/10.1021/acsomega.5c05879?ref=PDF
Doi https://doi.org/10.1021/acsomega.5c05879
Klíčová slova Biopolymers; Electrodes; Organic polymers; Plasma; Plastics
Přiložené soubory
Popis This study presents a rapid, environmentally friendly, and scalable activation method for 3D-printed poly(lactic acid)/carbon black (PLA/CB) electrodes using atmospheric air plasma under ambient conditions. The goal was to optimize the plasma activation time and compare its efficiency with conventional activation techniques using N,N-dimethylformamide (DMF) and sodium hydroxide (NaOH). Surface morphology, chemical composition, wettability, and electrochemical performance were systematically evaluated through scanning electron microscopy (SEM), Raman spectroscopy, XPS, contact angle measurements, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). Plasma treatment, as short as 5 s, effectively removed the PLA matrix from the electrode surface, enhanced surface roughness, hydrophilicity, and exposure of conductive carbon black particles, leading to increased electrochemical performance. Compared to chemical activation, 40 s of plasma activation yielded comparable performance with significantly shorter processing times (vs NaOH) and without hazardous solvents (such as DMF). Finally, the activated electrodes were successfully applied in the development, optimization, and validation of a novel electrochemical protocol for the determination of the antihypertensive drug amlodipine, revealing high sensitivity, a low limit of detection of 0.09 µM, precision (RSD of 6.6%), and recovery (97.1 and 105.4%) in pharmaceutical formulations. The findings demonstrate the promising potential of air plasma activation as a sustainable and efficient approach for preparing 3D-printed electrodes for analytical and sensing applications.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info